Detail Product

High-performance products designed for the toughest environments.

Genlitec GLT1600L-7VMK Portable Light Tower

Introducing the Genlitec GLT1600L-7VMK Portable Light Tower, your ultimate lighting solution for various outdoor applications. Whether you’re working on a construction site, responding to emergencies, or organizing an outdoor event, this light tower ensures reliable and efficient illumination to meet your needs.

Download Brochure

Product Detail

  • Model:GLT1600L-7VMK

Powered by KUBOTA

Generator Specification

GENLITEC Power lighting towers & generator sets are compliant with ISO 9001 and CE standard, which include the following directives:

  • 2006/42/ECMachinery
  • 2006/95/ECLow voltage
  • EN60204-1: 2006+A1: 2009, EN ISO 12100: 2010, EN ISO 13849-

1:2008, EN 12601: 2010

 

(1) PRP (Prime Power)

According to ISO 8528-1, prime power is the maximum power available during a variable power sequence, which may be run for an unlimited number of hours per year, between stated maintenance intervals. The permissible average power output during at 24 hours period shall not exceed 80% of the prime power. 10% overload available for governing purposes only.

 

(2) ESP (Standby Power)

According to ISO 8528-1. It is defined as the maximum power available, under the agreed operating conditions, for which the generating set is capable of delivering for up to 500 hours of operation per year (of which no more than 300 hours for continuative use) with the maintenance intervals and procedures being carried out as prescribed by the manufactures. No overload capability is available.

 

 

6 SETS / 20GP

 

12 SETS / 40GP

Mast lifting/lowing system Vertical, Manual Lifting Total power of lamps 4×400 watts LED

Fuel consumption (100% load) 2.0L/H Fuel tank capacity 100L

 

Standard Reference Conditions

Note: Standard reference condition 25℃ (77°F) air inlet temp. 100m (328ft) A.S.L 30% relative humidity. Fuel consumption date with diesel fuel with specific gravity of 0.85 and conforming to BS 2869: 1998 Class A2

 

DimensionStorageWorking
Length (L)2710mm3050mm
Width (W)1410mm2500mm
Height (H)2760mm7000mm
Net Weight810kg

Note: This parameters allows for some acceptable deviations.

 

 

Engine SpecificationAlternator Specification
 

 

 

 

 

MODEL: KUBOTA D1105-BGMODEL: GENLITEC S164G8
Cylinder number3Number of phaseSingle
Aspiration systemNaturalRated power (KW)8
Cooling methodWater cooledFrequency (Hz)50/60
Combustion systemE-TVCSPower factor (Cos Phi)1
Bore x Stroke (mm)78.0×78.4Temp. rise125K
Compression ratio22:1Insulation typeH class
Rated speed (RPM)1500Ambient temp.40℃
Displacement (L)1.123IP ratingIP23
Rated power (KW)8.4Excitation systemSelf-excited
Standby power (KW)9.5BearingSingle bearing
Fuel injection pumpBosch type PFR MD pumpCoatingVacuum impregnation
Injection NozzleThrottle typeVoltage regulatorA.V.R
Oil capacity (L)5.1CouplingFlexible disc
Charger Alternator capacity12V – 30A
Starter motor capacityDC 12V – 1.0A

 

 

 

 

 

Operation Mast SpecificationLamps Specification
Max. height of mast7mTotal power of lamps4 x 400 watts
Elevation systemVertical, MechanicalLamps typeLED
Raising/Lowing mast methodManual winchLight capacity4 x 60,000 lumen
Mast stages6Design lifetime50000 hours
Turning angle358° manuallyWorking temperature-25℃ ~ 50℃
Mast materialGalvanization Steel tubeLight coverage5 ~ 7 acres
Self-lock Winch1 x 1800lbsProtection gradeIP65

 

 

 

 

 

Chassis SpecificationController Panel Specification
Tow Hitch type“O” ring or Ball tow hitchControl moduleSMARTGEN HGM1790N
Brake typeMechanical hand brakeMain & Lamps BreakerDELIXI
Trailer structureSingle axleEmergency stopEquipped
Tyre size13 inchStarting methodElectric (Key start/Button))
Leveling jack type5 x ManualOutput Socket2 x 16A single phase

 

 

 

 

 

 

 

www.genlitecpower.com

 

 

LED Lights Detailed Technical Data
 

 

DescriptionLED Spotlight
Model numberSMD-400W
Light power400W LED
Installation method“U” type holder
ImageWorking temperature-40℃ ~ 50℃
Rated voltageAC 100-277V
Rated frequency50/60Hz
Power factor≥0.95
Design lifetime50000 hours
 

 

Protection gradeIP65
Certificates3C, UL, CE
Light cover materialAluminum
Radiate unitAluminum radiator
DimensionLighting angle25°, 40°, 60°, 90°, 110°
Luminous efficacy150Lm/W
Luminous flux60000Lm@5000K
Color temperature5700±300K
Color rendering indexRA≥70@5000K
Light sourceSingle unit LED
 

Standard distribution curve flux (90°)

 

 

 Standard Supply Scope

  • Industrialexhaust silencer l Flexible pipes l Float Battery charger l Base frame
  • Maintenancefree battery l Battery wires l Manual books l Digital control panel
  • Watercooling radiator l Wiring diagram l Tool kits l Main circuit breaker
  • V.R l Build-inbased fuel tank l Emergency stop button l Power output socket x 2
  • Weatherproof canopy l Top caution light l Ball/Ring hitch with safe chain

 

 

 

 

Optional Supply Scope

 

 

Engine

 

Alternator

 

Control Panel

 

Lamps

¡ QUANCHAI QC380Dengine¡ STAMFORD alternator¡ Smartgen ALC controller¡ 4x1500W lamps
¡ PERKINS 403D-11G engine¡ MECC ALTE alternatorSunrise & sunset start/stop¡ Spotlights
¡ YANMAR 3TNV76 engineRemote start/stop¡ 4x350W LED Spotlights
¡ Battery isolator¡ Deepsea DSEL401 MKII

¡ ComAp Inteli-Nano

¡ ABB breakers

¡ Power output socket x 2

¡ 4x1000W MH Lamps

 

 

 

www.genlitecpower.com

 

Control Panel

 

Configuration 

 

l Emergency stop button
l Protection MCB + Lamps & Socket circuit breaker
l Digital control module
l Power output socket x 1 (Single Phase)
l Weather proof controller box
l Alarm buzzer
 

 

 

 

Key FeaturesControl Module:SMARTGENHGM1790N
l Large back-lit icon LCD displayDigital input5
l Single / Three phase generator monitoringRelay output5
l AC phase voltage displayCommunication interfacePC
l Generator frequency displayAMFM/A
l Engine speed RPM displayAC System1P2W / 2P3W / 3P3W / 3P4W
l Battery voltage Vdc displayPhase voltage input0-300Vac
l Generator running hours displayFrequency range3Hz – 70Hz
l Engine coolant temperature displayStandby currentTBA
l Engine oil pressure displayAccuray1%
l Pre-alarm & shutdown alarm functionControl relay outputs3A/30Vdc
l Low oil pressure shutdown alarmDC supplyDC 8-35V
l Engine high temperature shutdown alarmOperating temp.-20 ~ +70℃
l Engine over speed shutdown alarm
l Generator over/under voltage shutdown alarm
l Generator over load shutdown alarm
l Start/Stop failure shutdown alarm
l IP65 rating offers increased resistance to water ingress

 

 

  • ControllerModule Options

 

 

SMARTGEN

 

COMAP

 

DEEPSEA

ALC404Inteli NanoDSEL401 MKII
 

 

 

Related Product

Open chat
Scan the code
Hello
Can we help you?